Secure the Power Cable to the PSU Screw Terminals
Test the Rocker Switch and PSU by connecting the Power Plug and turning the Switch ON
Be careful to NOT touch the screw terminals with your bare hands.
If the Green LED light turns on, it's a good sign
Use the Multimeter to make sure the output voltage is approximately 24V, adjust using the Philip Head Screw
Left 3 terminals are Positive Output
Middle 3 terminals are Ground/Negative Output
Once test is successful, Turn off the Power using the Switch and unplug the Power Plug