The air compressor switch should be off when you approach the machine. Flip it.
-
If it isn't off, report it.
-
-
-
Main power should be off when you start. Unlock it and turn it on.
-
If it is not off, report it.
-
If it is not locked, we don't have a process for that yet
-
-
-
Inspect the interior of the machine. Confirm the last user cleaned out the swarf and did not leave equipment in the machine.
-
Inspect the tray under the machine to make sure the last user cleaned out the swarf.
-
Inspect the automatic oiler. Make sure that it has oil and activates when the machine turns on.
-
-
-
If the E-stop does not need to be released, report it.
-
Release the E-stop.
-
Press the release button.
-
In the PathPilot Program, click "release" with the mouse or through the touch interface.
-